Vernier Callipers Master Hub: Least Count, Zero Error, Readings and Practice | eduPhysics

eduPhysics · Physics Practical Mastery

Vernier Callipers Master Hub

The complete vernier callipers learning center for CBSE, NEET and JEE physics, covering parts, least count, zero error, zero correction, reading the scale, practical measurements, numericals and exam practice.

LC = 1 MSD − 1 VSDleast count
Reading = MSR + VSR × LCtotal reading
Corrected = Observed − Zero errorzero correction
eduPhysics logo: a brass telescope on a stand with the words Excellence in Physics Education

Master the vernier callipers step by step

Vernier callipers measure lengths, outside and inside diameters and depths more precisely than a metre scale. They appear in the Class 11 practicals and in the experimental skills part of NEET and JEE Main. Follow this path from the instrument to exam practice:

  1. Know the instrument. Learn the parts and what each one measures.
  2. Find the least count. Work out the smallest reading from the two scales.
  3. Read the scale. Combine the main scale and vernier scale readings.
  4. Check zero error. Close the jaws and note any mismatch.
  5. Apply the correction. Subtract the zero error, with its sign.
  6. Measure and calculate. Find length, diameter, depth and volume, with errors.
  7. Practise. Solve numericals and NEET-style questions.

Parts of the vernier callipers

Main scaleVernier scaleOutside jaws Fixed jawMovable jawDepth rodLocking screw
PartFunction
Main scaleFixed scale, usually in centimetres and millimetres, with 1 MSD = 1 mm
Vernier scaleSliding scale that gives the fraction of the smallest main scale division
Outside jawsHold the object to measure its length or outer diameter
Inside jawsFit inside a hollow object to measure its internal diameter
Depth rod (strip)Slides out from the end to measure the depth of a beaker or hole
Locking screwFixes the vernier scale so that a reading can be taken without it moving

Least count

The vernier scale has N divisions that together equal (N − 1) divisions of the main scale. Each vernier division is therefore a little shorter than a main scale division, and the difference is the smallest length the instrument can measure.

LC = 1 MSD − 1 VSD = (value of 1 MSD) / NIf 10 VSD = 9 MSD and 1 MSD = 1 mm, then LC = 0.1 mm = 0.01 cm
1 MSDVernier divisions (N)Least count
1 mm100.1 mm = 0.01 cm
1 mm200.05 mm = 0.005 cm
1 mm500.02 mm = 0.002 cm

How to read the scale

  1. Main scale reading (MSR): note the last main scale division that lies to the left of the zero of the vernier scale.
  2. Vernier scale reading (VSR): find the vernier division that coincides exactly with any main scale division.
  3. Total reading:
    Observed reading = MSR + (VSR × LC)
  4. Correct for zero error before you use the reading (see below).

Example: MSR = 2.3 cm, the 6th vernier division coincides, LC = 0.01 cm. Reading = 2.3 + 6 × 0.01 = 2.36 cm.

Zero error and zero correction

The zero error is the reading the instrument shows when the jaws are closed, when it ought to show zero. Always check it before you start.

Positive zero error

The zero of the vernier lies to the right of the main scale zero. If the n-th vernier division coincides:

Zero error = + n × LC

Negative zero error

The zero of the vernier lies to the left of the main scale zero. If the n-th division coincides:

Zero error = − (N − n) × LC
Zero correction = − Zero error    Corrected reading = Observed reading − Zero error

For example, a positive zero error of +0.02 cm means every reading is 0.02 cm too large, so subtract it. A negative zero error of −0.02 cm means every reading is too small, so add 0.02 cm.

Practical measurements

Length or outer diameter

  1. Check and record the zero error.
  2. Place the object between the outside jaws, and close them gently.
  3. Tighten the locking screw and read the scale.
  4. Repeat at three positions, and at right angles for a diameter.

Inner diameter and depth

  1. Insert the inside jaws into the hollow object, and open them until they touch the walls.
  2. For depth, rest the end of the body on the rim and push the depth rod to the bottom.
  3. Lock the screw and read the scale.
  4. Repeat and take the mean.

Observation table

TrialMSR (cm)VSR (div)Observed (cm)Corrected (cm)
1
2
3
Mean

The volume of a solid cylinder is V = πd²l/4, and the volume of a hollow vessel is V = πd²h/4 from its inner diameter d and depth h. A squared quantity such as d contributes twice as much to the percentage error, so measure it with extra care.

Precautions

  • Check the zero error each time, and apply the correction with its sign.
  • Do not tighten the jaws hard on the object.
  • Look straight at the scale to avoid parallax error.
  • Take several readings at different positions, and use the mean.
  • Lock the screw before you read the scale.

Vernier callipers and screw gauge

FeatureVernier callipersScrew gauge
Least count (typical)0.01 cm (0.1 mm)0.01 mm
MeasuresLength, outer and inner diameter, depthThickness of sheets, diameter of thin wires
RangeAbout 12 to 15 cmAbout 0 to 25 mm
Common errorsZero error, parallaxZero error, backlash error

For the other instrument, see the Screw Gauge Master Hub.

Free vernier callipers calculator

Least count, observed reading and corrected reading

LC = 1 MSD / N, Observed = MSR + VSR × LC, Corrected = Observed − Zero error

With the defaults, MSR = 23 mm (2.3 cm) and the 6th division coincide, with a positive zero error from the 2nd division. Use it to check your own readings, and show full working in the exam.

Worked numericals

1. Least count. 10 vernier divisions equal 9 main scale divisions, and 1 MSD = 1 mm. Find the least count.

1 VSD = 0.9 mm, so LC = 1 − 0.9 = 0.1 mm = 0.01 cm.

2. A finer instrument. 20 vernier divisions equal 19 main scale divisions, with 1 MSD = 1 mm. Find the least count.

LC = 1 MSD / N = 1/20 = 0.05 mm = 0.005 cm.

3. Positive zero error. The main scale reading is 2.3 cm and the 6th vernier division coincides. LC = 0.01 cm, and the zero error is +0.02 cm. Find the true reading.

Observed = 2.3 + 6 × 0.01 = 2.36 cm. Corrected = 2.36 − 0.02 = 2.34 cm.

4. Negative zero error. With the jaws closed, the 8th of 10 vernier divisions coincides, and the vernier zero is to the left of the main zero. LC = 0.01 cm. A rod reads 3.45 cm. Find its length.

Zero error = −(10 − 8) × 0.01 = −0.02 cm. Corrected = 3.45 − (−0.02) = 3.47 cm.

5. Volume with error. A cylinder has length l = 5.60 ± 0.01 cm and diameter d = 2.20 ± 0.01 cm. Find its volume and the error.

V = πd²l/4 = π(2.20)²(5.60)/4 ≈ 21.3 cm³.
ΔV/V = 2(Δd/d) + Δl/l = 2(0.01/2.20) + 0.01/5.60 ≈ 0.0109, or 1.1%.
ΔV ≈ 0.23 cm³, so V = 21.3 ± 0.2 cm³.

Practice questions

Q1. The least count of a vernier callipers is the difference between:
  • (A) 1 MSD and 1 VSD
  • (B) 1 MSD and 2 VSD
  • (C) 1 VSD and 2 MSD
  • (D) 10 MSD and 1 VSD

Answer: (A). LC = 1 MSD − 1 VSD.

Q2. With the jaws closed, the zero of the vernier is to the right of the main scale zero, and the 4th division coincides. LC = 0.01 cm. The zero error is:
  • (A) +0.04 cm
  • (B) −0.04 cm
  • (C) +0.06 cm
  • (D) −0.06 cm

Answer: (A). A vernier zero to the right gives a positive error, equal to n × LC = 4 × 0.01 = +0.04 cm.

Q3. A rod reads 4.52 cm on a vernier callipers with a zero error of +0.03 cm. Its true length is:
  • (A) 4.55 cm
  • (B) 4.49 cm
  • (C) 4.52 cm
  • (D) 4.46 cm

Answer: (B). Corrected = observed − zero error = 4.52 − 0.03 = 4.49 cm.

Q4. Which part of the vernier callipers is used to measure the internal diameter of a tube?
  • (A) The depth rod
  • (B) The outside jaws
  • (C) The inside jaws
  • (D) The locking screw

Answer: (C). The inside jaws fit inside a hollow object and open until they touch its walls.

Viva questions

What is the principle of the vernier scale?

The vernier scale divisions are slightly shorter than the main scale divisions, so the difference between them lets you measure a fraction of the smallest main scale division.

Why is a vernier callipers more precise than a metre scale?

A metre scale reads to 1 mm at best, while a vernier callipers with a least count of 0.1 mm reads ten times more precisely.

What is zero error, and does it change with the object?

It is the reading shown when the jaws are closed, and it should be zero. It is a property of the instrument, so it stays the same for all objects and must be applied to every reading.

Why do we take readings at different positions and in two perpendicular directions?

The object may not be perfectly uniform or circular, so the mean of several readings gives a more reliable value.

What is parallax error, and how is it avoided?

It is the apparent shift in a reading when the scale is viewed from an angle. Look straight at the scale, perpendicular to its surface.

Vernier callipers FAQs

What is the least count of a vernier callipers?

The least count is the difference between one main scale division and one vernier scale division. For a common vernier with 1 MSD = 1 mm and 10 vernier divisions equal to 9 main scale divisions, it is 0.1 mm, or 0.01 cm.

How do you find the zero error of a vernier callipers?

Close the jaws and look at where the vernier zero lies. If it is to the right of the main zero, the error is positive, and equals the coinciding division times the least count. If it is to the left, the error is negative, and equals minus the number of divisions short of the full count, times the least count.

How do you apply zero correction?

Subtract the zero error from the observed reading, using its sign. A positive error is subtracted, and a negative error is added.

What can a vernier callipers measure?

It can measure the length and outer diameter of an object with the outside jaws, the internal diameter of a hollow object with the inside jaws, and the depth of a beaker or hole with the depth rod.

Keep learning on eduPhysics

Practical books

The least count is the difference between one main scale division and one vernier scale division. For a common vernier with 1 MSD = 1 mm and 10 vernier divisions equal to 9 main scale divisions, it is 0.1 mm, or 0.01 cm.

Close the jaws and look at where the vernier zero lies. If it is to the right of the main zero, the error is positive and equals the coinciding division times the least count. If it is to the left, the error is negative and equals minus the number of divisions short of the full count, times the least count.

Subtract the zero error from the observed reading, using its sign. A positive error is subtracted, and a negative error is added.

It can measure the length and outer diameter of an object with the outside jaws, the internal diameter of a hollow object with the inside jaws, and the depth of a beaker or hole with the depth rod.

Share this:

Like this:

Like Loading…